XY-100MW觸摸屏快速水分測(cè)定儀XY-100MW

價(jià)格
電議

型號(hào)
XY-100MW觸摸屏快速水分測(cè)定儀XY-100MW

品牌

所在地
暫無

更新時(shí)間
2024-03-25 13:22:28

瀏覽次數(shù)

    XY-100MW觸摸屏快速水分測(cè)定儀XY-100MW

    XY-100MW觸摸屏快速水分測(cè)定儀XY-100MW

     

    1.加熱方式:鹵素?zé)?br /> 2.可讀性:1mg
    3.全不銹鋼加熱腔體
    4.精鑄鋁殼
    5.溫度/時(shí)間可調(diào)
    6.20組數(shù)據(jù)儲(chǔ)存
    7.動(dòng)態(tài)分析
    8.精密溫度控制
    9.支持多語(yǔ)言切換
    10.支持語(yǔ)音功能


    鹵素水分測(cè)定儀使用注意事項(xiàng):

    1.鹵素水分測(cè)定儀是用來測(cè)量樣品中的水份含量,用于其他任何用途都可能會(huì)對(duì)個(gè)人造成傷害并

    損壞儀器。

    2、使用前請(qǐng)務(wù)必認(rèn)真閱讀說明書,勿在不符合要求的環(huán)境條件下使用。

    3、鹵素快速水分測(cè)定儀僅供熟悉樣品性質(zhì)和受訓(xùn)過的人員使用。

    4、鹵素快速水分測(cè)定儀電源為三插帶接地插座,禁示斷開儀器接地線或使用沒有良好接地的電源。

    5、儀器的周圍應(yīng)確保有足夠的空間,以免熱量堆積和過熱。

    6、由于儀器周圍的加熱單元四周區(qū)域會(huì)變熱,請(qǐng)勿在儀器周圍放置易燃物品。

    7、測(cè)試結(jié)束后由于樣品本身和加熱單元和其容器仍會(huì)很燙,因此在取走樣品時(shí)應(yīng)小心謹(jǐn)慎。

    8、在加熱烘干過程中,環(huán)形加熱無件溫度會(huì)達(dá)到400℃。因此請(qǐng)勿打開或接觸加熱單元。如需要打

    開請(qǐng)斷開電源并等待,直至其完全冷卻。

    9、對(duì)于可燃或易燃物品、含溶劑基質(zhì)、加熱時(shí)會(huì)產(chǎn)生可燃或易爆氣體的基質(zhì),特別小心,因?yàn)檫@

    些樣品,可能會(huì)對(duì)人體產(chǎn)生危害或損壞設(shè)備。因此,在測(cè)定這種樣品時(shí),應(yīng)使操作加熱溫度足夠低

    以防形成火焰或爆炸物,并戴好護(hù)目鏡等防護(hù)用具。如果對(duì)樣品的可燃性不是很了解時(shí),測(cè)試樣品

    量應(yīng)盡量少。這種情況下,儀器應(yīng)有專人看管,以防萬(wàn)一,實(shí)驗(yàn)前請(qǐng)自行做好風(fēng)險(xiǎn)分析。

    10、對(duì)含有毒性元素的基質(zhì),這種基質(zhì)只能在有良好通風(fēng)設(shè)備的條件下進(jìn)行加熱烘干。

    11、加熱烘干時(shí)產(chǎn)生腐蝕性蒸汽的基質(zhì),在測(cè)量這種基質(zhì)的樣品時(shí),因蒸汽會(huì)凝結(jié)在較冷的外殼部

    分產(chǎn)生腐蝕,建議減少樣品克重。

     

    XY-100MW touch screen rapid moisture tester XY-100MW

    XY-100MW touch screen rapid moisture tester XY-100MW

    1 heating methods: halogen lamps

    2 readability: 1mg

    3 stainless steel heating chamber.

    4 cast aluminum shell

    5 temperature / time adjustable

    6.20 sets of data storage

    7 dynamic analysis

    8 precision temperature control

    9 support for multi language switching

    10 support voice function

    Note the use of halogen moisture analyzer:

    1 halogen moisture analyzer is used to measure the moisture content in the sample used for any other purposemay cause injury and personal

    Damage the instrument.

    2 before use please read the instructions carefully noton the do not meet the requirements of the environmental conditions.

    3 by halogen Monisture detector is trained with sample properties and professional use.

    4 halogen rapid moisture meter power supply for the threeplug sockets with grounding banning open instrumentgrounding wire or not well grounded power.

    Around 5 the instrument should ensure that there isenough space so as to avoid the heat accumulation and overheating.

    6 because the heating element around the area around the instrument becomes hot do not place flammable itemsin the instrument around.

    7 after the test the sample itself and the heating unit andits container is very hot so in the sample is removedshould be circumspect.

    8 in the drying process the annular heating temperaturecan reach 400 ℃ without. Therefore please do not open or contact heating unit. Such as the need to fight

    Please disconnect the power and wait until it is fullycooling.

    9 for flammable or combustible articles solvent containingmatrix heating will produce flammable or explosive gas matrix especially careful because this

    Some samples may cause harm or damage to equipmenton the human body. Therefore in the determination of thesamples should enable the operation of the heatingtemperature is low enough

    To prevent the formation of a fire or explosives and weargoggles and protective equipment. If the flammability of samples is not very understanding the test sample

    Quantity should be as little as possible. In this case the instrument should watch make provision against a rainy day please do risk analysis before the experiment.

    10 the matrix containing toxic elements the matrix only for heating and drying in the well ventilated condition.

    Matrix corrosion steam 11 heating and drying themeasurement of the matrix of the sample since the steamcondenses on the cooler.

    The corrosion is proposed to reduce the sample weight.

    以上信息由企業(yè)自行提供,信息內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),儀器儀表交易網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。
    溫馨提示:為規(guī)避購(gòu)買風(fēng)險(xiǎn),建議您在購(gòu)買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

    其他推薦產(chǎn)品

    CHECK LINE 頻閃儀 ESL200
    CHECK LINE 頻
    ¥6,100.00
    LSCG數(shù)顯PPM級(jí)可燃?xì)怏w檢測(cè)儀美國(guó)CPS原裝進(jìn)口欣銳儀器代理測(cè)爆儀
    LSCG數(shù)顯PPM級(jí)可燃
    ¥2,150.00
    3116A日本ACO測(cè)振儀數(shù)字振動(dòng)分析儀原裝進(jìn)口震動(dòng)儀代理
    3116A日本ACO測(cè)振
    ¥6,500.00
    LSCG數(shù)顯PPM級(jí)可燃?xì)怏w檢測(cè)儀美國(guó)CPS原裝進(jìn)口代理測(cè)爆儀
    LSCG數(shù)顯PPM級(jí)可燃
    ¥2,150.00
    TIF8800X美國(guó)TIF可燃?xì)怏w檢測(cè)儀
    TIF8800X美國(guó)TI
    ¥2,650.00
    Bosch汽車事故數(shù)據(jù)讀取工具-CDR
    Bosch汽車事故數(shù)據(jù)讀
    ¥390,000.00
    4105A-H日本克列茨接地電阻測(cè)試儀
    4105A-H日本克列茨
    ¥3,540.00